Products Architecture A.055

A.055

Hinged door system, with or without thermal break, for large solutions.

Tested system, by an accredited body, for severe use: 1,000,000 opening cycles.

Request info

Side-hung door system, with or without thermal break, of large dimensions. A solution tested, by an accredited body, for severe use: 1,000,000 opening cycles.

The system has different opening typologies, from side-hung opening to the inside or outside, pivoting opening (rotation on a vertical axis) and also, swing opening.

Each window can have sashes with a maximum height and width of 3000 mm and 1200 mm, respectively, and the weight varies according to the selected opening type.

The system has several sill profiles: one solution for a more effective sealing, and another, consisting of a smooth sill to enhance the accessibility of the dwellings. Multipoint lock, anti-panic bar/cremone and anti-pinch solution were introduced.

A.055
Sistema de Batente A
Sistema de Batente A
Sistema de Batente A
Sistema de Batente A
<
>
Request for InformationLearn more about the product
Name
Company
E-mail 
Phone
District
Mensagem

Side-hung opening to the inside

Side-hung opening to the inside

Side-hung opening to the outside

Side-hung opening to the outside

Swing opening

Swing opening

Pivoting (on vertical axis)

Pivoting (on vertical axis)

Technical Details

Frame depth: 55 mm
Sash depth: 55 mm
Sash view: 168 mm
Meeting section view: 216 mm
Frame and sash cut: 45º / 90º
Maximum sash width: 1200 mm
Maximum sash height: 3000 mm
Maximum sash weight: 250 Kg
Blazing: 10 mm / 12 mm and 26 mm to 36 mm
Bicolor: Sim
Application: New construction / Renovation

Performance

Initial Type Test
Opening door made up of two rotating leaves that open inwards.
Dimension: 1600mm x 2000mm

AIR PERMEABILITY
Class 4
EN 12207
WATER PROOFING
E1350
EN 12208
WIND PRESSURE RESISTANCE
C5
EN 12210



THERMAL TRANSMISSION COEFFICIENT:
Uw=2.3W/m2K-1
EN ISO 10077-1
Dimension: 1400 mm x 2700 mm
Glass Ug 0.9W/m2K-1

ACOUSTIC PERFORMANCE
39 (0;-3) dB
Glass 42 (-1;-3) / área < 2,7 m2
Rel. Nº ACU 459/2012 | Nº ACL 206/12
Org. Notified Nº 2211
Variable values according to the typology and composition of the glass.
Uw - Thermal transmission coefficient. The smaller, the better the thermal performance.
Rw - Frame acoustic insulation index. The bigger, the better the sound insulation coefficient.


 

 

Technical documentation

Maintenance manual
Download
Architecture Brochure
Download
Slider imagens 1
Ask us for a quote Describe your project to us.
Name 
E-mail  
Contact 
Subject 
Message